
If your meter is not listed on the dialog, just click Search. If your meter is listed on the Find Meters dialog, select it, then click Search. On the Session Setup page, click the Find Meter button. Connect your color meter to the CalMAN computer. Initial Setup section In the Initial Setup section of the Color Cube workflow, step through the following pages: a. Create Display Calibration 3D LUT Proceed through each step of the Color Cube workflow in the normal fashion, using the following notes for madvr specifics. Validate the calibrated display performance. Create a display calibration 3D LUT file for a video display that is driven from madvr and automatically load the 3D LUT file into madvr.

Display Calibration Follow this procedure to: a. If CalMAN is running on the display to be calibrated, make the Test Pattern Generator window as small as possible, while still providing a full target for your color meter. Load the Color Cube workflow - in the CalMAN main menu, select Open Workflow Template, then select Color Cube (3D LUT).

Note: It will be more convenient to run CalMAN either on a separate computer from the HTPC that is driving the display to be calibrated or on a second monitor on the HTPC.Ģ Open CalMAN Color Cube workflow 1. If a Windows firewall alert appears, select the desired options and click Allow access. Enable LAN Access If CalMAN will be running on a separate computer from the HTPC that is driving the display to be calibrated: On the HTCP that is driving the display to be calibrated - 1. Position the madvr Test Pattern Generator window in the center of the display to be calibrated. In the madvr folder on the HTPC, locate and run the file, madtpg.exe. Required madvr Software Version: Version or newer Required CalMAN Software Version: Version or newer Required CalMAN Workflow: Color Cube (3D LUT) workflow Software Setup Open madvr Test Pattern Generator 1. madvr alters its output signal, according to the LUT data, to correct the display performance to very accurately comply with the selected video standard (e.g. CalMAN then automatically loads the calibration LUT file into madvr to apply calibration correction to the display. CalMAN controls the Test Pattern Generator as it creates an optimized calibration LUT file for the madvr. The generator automatically produces the required test patterns (patches) as CalMAN measures the display that is driven from madvr. 1 madvr 3D LUT Calibration Quick Start Guide CalMAN Display Calibration Software interfaces directly with the Test Pattern Generator that is provided with the madvr video renderer.
